Loading...

Halcyon GreenFlash solid state sensor (COAX)

In stock
SKU
80.300.004
Rating:
0%

This sensors is tested and approved for use in the:
Halcyon Symbios™CCR
GBM CCR 
They are not endorsed for and may not work with any other rebreather. They’re offered solely as a replacement or upgrades for GBM CCR and Halcyon Symbios™CCR

£576.00 £480.00
In stock

Call us on +44 (0)1933 681255 (option 1) to order by phone

This sensors is tested and approved for use in the:
Halcyon Symbios™CCR
GBM CCR 
They are not endorsed for and may not work with any other rebreather. They’re offered solely as a replacement or upgrades for GBM CCR and Halcyon Symbios™CCR

 

GREENFLASH O2 SENSOR

A solid state oxygen sensor, based on fluorescence quenching. The sensing layer incorporates special dyes, which fluorescent when exposed to green light. The amplitude as well as the lifetime of the fluorescence light corresponds to the amount of oxygen.

SMART SENSOR INTERFACE

Although the GREENFLASH O2 sensor is a digital sensor, is can also output an analog signal thanks to our patent pending smart interface technology. This allows using the sensor in already existing life support system,  originally designed for galvanic O2 sensors.

SERVICE INTERVAL

Our GREENFLASH O2 Sensor has a lifetime of more than 5 years. In contrast, traditional galvanic sensors need to be replaced in 12 month intervals.

MEASUREMENT SPECIFICATIONS

Standard Range: 10..100% O2

Extended Range: 0.1 .. 2 bar pO2 

Response time t63: <2s

Accuracy: compliant to ISO 80601-2-55

RoHS compliant

MECHANICAL SPECIFICATIONS

Gas connection: M16x1mm thread

Diameter: 29mm

Height 28mm

Battery: CR2477

Housing Material: Polycarbonate and ABS

 

The GREENFLASH SOLID STATE O2 SENSOR features an O2 sensitive sensor spot, which incorporates a special colour dye. When this colour dye is excited with green light, it starts fluorescing and emits red light. O2 quenches the fluorescence, thus the higher the partial pressure of O2 the lower is the amplitude and lifetime of the red fluorescence signal.

 

The GREENFLASH SOLID STATE O2 SENSOR excites the sensors spot with a green light modulated with a sinusoidal signal. The fluorescence signal is acquired with a high speed ADC: measured. Then the  GREENFLASH SOLID STATE O2 SENSOR performs a Fast Fourier Transformation to calculate amplitude and lifetime of the fluorescence, a temperature compensation, and finally calculates the pO2 based on calibration values that were obtained during the production process of the sensor.

 

The GREENFLASH SOLID STATE O2 SENSOR switches automatically between 3 operational modes:

 

              Sleep Mode: If the sensor is not installed, it is in Sleep Mode to conserve battery power. In this mode it measures once each 20s if it is installed in a measurement device.

              Standby Mode: In this mode, it performs a pilot measurement each 15s. If then the measured pO2 is greater than 0.3 bar, the sensor will enter measurement mode.

              Measurement Mode:  In this mode, it will perform a measurement each 2 seconds and will, depending on the electrical interface, output analog or digital data.  Once the pO2 falls below 0.3 for at least one hour, the sensor will exit measurement mode and return to Standby Mode.

 

caution

Bright light and in particular fluorescence light can interfere and cause incorrect sensor readings. Use the sensor inside the housing of a measurement system or in a light-protected environment.

 

Troubleshooting

 

Problem:

 

Solution:

The GREENFLASH SOLID STATE O2 SENSOR  produces fluctuating sensor signals

 

Protect the sensor from ambient light

 

 

 

The GREENFLASH SOLID STATE O2 SENSOR   blinks green once each 15s, but does neither output digital or analog data

 

Expose the sensor to a pO2  greater than 0.3 bar

 

 

Check the electric connection

 

 

Check if the input impedance of the measurement system the sensor is connected to, matches the specification of  the GREENFLASH SOLID STATE O2 SENSOR

 

   

The GREENFLASH SOLID STATE O2 SENSOR  is installed in a measurement device but does not blink green once each 15s

 

Check the electric connection

 

 

Check if the input impedance of the measurement system the sensor is connected to matches the specification of  the GREENFLASH SOLID STATE O2 SENSOR

 

 

Replace the battery, if the voltage of the battery is below 2.3V

 